Description
Data sheet
Structure
Standard
Galvanised steel
On request
Optional RAL coating or stainless steel AISI 304
Tests
Standard UNI EN 13241/CE
Reference standard: UNI EN 13241-1
Wind load resistance: in accordance with EN12424 / EN12444 – Class 2 (depending on dimensions)
Water penetration resistance: in accordance with EN12425 / EN12489 – Class 5
Air permeability: in accordance with EN12426 / EN12427 – Class 1
Opening safety: in accordance with EN12453 / EN12445
Mechanical aspects: in accordance with EN12604 / EN12605
Operating cycles: EN12604 / EN12605 – 1,000,000 cycles
Values may vary depending on the door dimensions
Safety
Components
Photocells
For 2 / 22 (cat. 3) classified zones:
II 3G Ex nA IIC T6 Gc, Top -20 °C +60 °C, IP67
II 3D Ex tc IIIC T100 °C Dc, -20 °C +60 °C, IP67
For 1 / 21 (cat. 2) classified zones (same photocells with enclosure):
II 2G Ex d IIC T6 Gc
II 2D Ex tb IIIC T85 °C Db
Emergency stop via external button or control panel input
Push-button enclosure:
II 2G Ex d IIC T6, Top -20 °C +40 °C, IP66
II 2D Ex td A21 T85, Top -20 °C +40 °C, IP66
Emergency release
Manual opening
Opening with supplied crank
UPS (not installable in ATEX-certified zones)
Special requests
Do you need a special feature for this product?
Log in or register
Discover all the features of this logistics product to see if it is the right one for your business.
Drawings
Brochure
ZipGOAtex
Products for chemical and mining companies.
Industrial rapid door dedicated to environments that have physical characteristics of potential deflagration or explosion.
So why choose this rapid door?
1. In accordance with ATEX
EN 60079 – X standards cover a number of aspects related to potentially explosive atmospheres. These standards, which are also the basis of EU Directive 2014/34 (ATEX), describe the types of explosion protection for electrical equipment, as well as the assessment or classification of hazardous areas in an installation. Therefore, on the basis of these regulations we have developed an ad hoc door.
2. Hermetic
The special structure and explosion-proof components are able to operate in constant harmony with the surrounding environment, always providing the highest degree of tightness and protection from possible triggering agents.
3. Why galvanised steel or AISI 304 stainless steel
At the regulatory level we know that it is possible to develop products both in galvanised steel and stainless steel in order to avoid providing an ignition source between the structural components and the chemicals handled by the company. We specify that it was the desire of the R&D department to formulate a solution that would not only look at the legislation but also combine a philosophy in line with the highest standards of protection.




















2 reviews for ZipGO Atex